:: Volume 15, Issue 4 (September & October 2010 2010) ::
pajoohande 2010, 15(4): 157-164 Back to browse issues page
Surveillance of ventilator- associated pneumonia in neonatal intensive care unit: characteristics, risk factors and outcome
Seyed Abolfaz Afjeh * , Mohammad Kazem Sabzehei , Seyed Abdollah Karimi , Ahmadreza Shamshiri
, a_afjeh@sbmu.ac.ir
Abstract:   (14759 Views)
Background and Aim: Ventilator Associated pneumonia (VAP) occurs 48 hours or later after initiation of mechanical ventilation. VAP is the second most common nosocomial infection in neonatal intensive care unit (NICU). Therefore, it is necessary to determine the rate, characteristics, risk factors and outcome of VAP in NICU patients. Materials and Methods: A prospective cohort study was conducted at the Mahdiyeh Hospital over a period of 1 year on all neonates who were admitted to NICU and required mechanical ventilation for more than 48 hours. Diagnosis of VAP was made according to the definition of nosocomial pneumonias for patients younger than 12 months by CDC (center for disease control and prevention). Risk factors for developing VAP such as birth weight, gestational age, gender, duration of mechanical ventilation, length of hospital stay and drugs were studied. The significant risk factors in univariate analysis were subjected to multivariate regression to determine independent predictor of VAP and mortality. Results: VAP occurred in 14 of 81 neonates (17.3%). The rate of VAP was 9 per 1000 ventilator days. The most common bacteria isolated from endotracheal aspirate were gram negative organisms (Ecoli (21.4%), Klebsiella (21.4%) and Pseudomonas (14.1%)). By multivariate analysis, duration of mechanical ventilation (B odd's ratio= 0.07, P=0.001) and anti-acid therapy (OR= 0.22, P=0.098) were two single independent risk factors for VAP. Two neonates with VAP died (14.3%) and multivariate analysis revealed that duration of mechanical ventilation (B odd's rate= -0.04, P=0.01), low birth weight (B odd's ratio= 0.002, P<0.001) and purulent sputum (hazard risk= 0.25, P=0.006) were independent predictor of mortality. Patients with VAP also had prolonged stay in NICU (59 vs 27 days). ‍Conclusion: VAP occurred at significant rate among mechanically ventilated NICU patients. Additional studies are needed to investigate how to prevent VAP and interventions needed.
Keywords: Infant, Newborn, Pneumonia, Ventilator- associated, Intensive Care Units, Neonatal, Risk Factors, Incidence
Full-Text [PDF 209 kb]   (4153 Downloads)    
Type of Study: Original | Subject: Medicine
Received: 2017 | Accepted: 2017 | Published: 2017


XML   Persian Abstract   Print



Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 15, Issue 4 (September & October 2010 2010) Back to browse issues page