[Home ] [Archive]    
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Subscription::
Contact us::
Site Facilities::
Webmail::
::
Search in website

Advanced Search
Receive site information
Enter your Email in the following box to receive the site news and information.
:: Volume 17, Issue 4 (September & October 2012 2012) ::
pajoohande 2012, 17(4): 203-209 Back to browse issues page
Survey of one year neonatal resuscitation in the delivery room of Mahdieh Hospital, Tehran
Seyyed Abolfazl Afjeh * , Mohammad Kazem Sabzehei , Fatemeh Esmaili
Assistant Professor, Pediatric Infections Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran , : a_afjeh@sbmu.ac.ir
Abstract:   (10578 Views)
Background and Aim: Timely identification and prompt resuscitation of newborns in the delivery room may cause a decline in neonatal asphyxia. The aim of this study was to identify risk factors that result in the resuscitation of newborns at birth in Mahdieh Hospital. Materials and Methods: This cross sectional study was done during one year and risk factors for neonatal resuscitation, level of resuscitation and short outcomes (survival or death), wre extracted from charts and were analyzed. Results: During the study period, 4692 neonates were delivered 97.7% did not require respiratory assistance. 2.3% needed resuscitation with bag and mask in the delivery unit of these, 1.6% responded to bag and mask ventilation while 0.65% needed endotracheal intubation and 0.3% were given chest compressions. Epinephrine/volume expander was administered to 0.2%. In multiple regression analysis, low birth weight, meconium stained liquor and chorioamnionitis were revealed as independent risk factors for advance resuscitation. Neonatal mortality was 10 in 1000 live birth asphyxia with 23.4% was one of major causes of neonatal mortality. Incidence of asphyxia was 0.3%, 24.7% and 50% in neonates without resuscitation, basic resuscitation and advance resuscitation, respectively. ‍Conclusion: It seems that low birth weight, meconium stain amniotic fluid and chorioamnionitis are major risk factors for neonatal resuscitation in delivery room.
Keywords: Infant, Newborn, Delivery Rooms, Risk Factors
Full-Text [PDF 153 kb]   (2324 Downloads)    
Type of Study: Original | Subject: Medicine
Received: 2017 | Accepted: 2017 | Published: 2017
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Seyyed Abolfazl Afjeh, Mohammad Kazem Sabzehei, Fatemeh Esmaili. Survey of one year neonatal resuscitation in the delivery room of Mahdieh Hospital, Tehran . pajoohande 2012; 17 (4) :203-209
URL: http://pajoohande.sbmu.ac.ir/article-1-1383-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 17, Issue 4 (September & October 2012 2012) Back to browse issues page
Persian site map - English site map - Created in 0.05 seconds with 36 queries by YEKTAWEB 4645